TECHCOAT CLEAR is a two component general purpose clear coating, which can be applied on various surfaces like Metal, Concrete, Wood, Asbestos Floors & certain plastics like PVC, Oxyflouroethylene etc. It is a chemically curing type product which forms a clear impervios, tough, hard &abrasion resistant, waterproof and durable clear coating. It remains unaffected by water, dilute acids, alkalies &various other chemical solution.

 

 

Technical Information

Characteristics
 Mixing ratio
Part I : Part II
80:20 pbw
 Consistency of the mix   Ready to use, brushable
 Application time (pot life) at 30ºC
 Surface dry time
 Tack free time
 Hard dry time
 Complete curing time

2-3 hours.
30-40 minutes
2-3 hrs.
24 hrs.
72 hours minimum

 Recoatibility time at 30ºC
 Finish
 Dry film thickness

10 to 12 hours
Smooth & glossy
40-45 microns per coat.

Coverage
    Concrete
    Steel





35-40 sq.ft./ltr/coat
50-60 sq. ft./ltr/coat


Features / Advantages

  • Cold curing, cures at ambient temperature
  • Chemically curing type, no external curing is required.
  • Bonds strongly on cement concrete, cement plaster, asbestos, mild steel, wood, stones etc.
  • Cures to a tough, flexible and abrasion resistant coating .
  • Resistant to water, dilute acids, alkalies, oils & various other chemical solutions.
  • Resistant to fungus & micro-organism growth.
  • Performs well in service temperature range of -20°C to +3o°c.
  • Being clear in nature, it does not affect the original appearance / colour of surface.

Typical Application

  • Protection / waterproofing of external vertical walls, build ing roofs, terraces from' external disturbances
  • Protection of metal, wood , asbestos from external disturbances like humidity, U-V rays etc .
  • Additional protection to top coat from weathering, corrosion etc.
  • Can be applied on concrete / metallic floor as a scratch proof abrasion resistant

Mixing
Mix Part I & Part II in their individual original containers. Pour the entire quantity (content) of the Part II tin into the Part I tin. Mix both the parts thoroughly by spatula to a homogenous mixture for atleast 5 to 10 minutes.

Method of Application
By brush or airless spray.

Thinner

TECHCOAT CLEAR is normally supplied at application viscosity. However 5% of solvent, Xylene or Toluene can be used to overcome the problem of quicker drying due to hot substrate and sunheat.

Direction for use

Surface preparation

Surface preparation is.of great importance and will affect the degree of adhesion and life of the coating.
The surface should be absolutely dry, free from dust, loose particles, damaged plaster, oils, greases, mould release agents and dirt. Thorough wire brushing of the surface is a must.
Previously applied bituminous compound / coating should be removed to the extent possible. The new concrete I plastered surface should be cured with water for minimum 28 days.
Clean the dust by washing it with water & allow the surface to dry completely. If the surface is too old and saturated with dirt, treatment with 15-20% hydrochloric acid is recommended with thorough wire brushing. Wash the surface with water till neutralisation. Allow the surface to dry completely.

Waterproofing of Roof Terrace & parapet walls.

  • Repair damaged cement plaster or concrete mortar with Mastercrete M-81, acrylic modifier.
  • Use 5-10% by weight of M-81 on cement weight for the preparation of mortar.
  • Before placing mortar, apply bond coat of O.P. cement & M-81 (2:1 parts by wt). M-81 improves the compression, flexural strength & bonding of new mortar with old concrete surfaces.
  • Cure the repaired mortar for 7 days to 28 days with water before application of Techcoat.
  • Fill the cracks upto 2mm width with Techoxy or Techmast with O.P. cement white / grey (1:2 parts by wt.) putty. Allow to dry for overnight 24 hours.
  • Seal the cracks wider than 2mm with polysulphide sealant Techseal RDL-940 & Primer RDL-942 after making the joint / groove of 5x5 mm or 10x10mm into the crack
  • For large terrace (>3000sq.ft) provide dummy joints at span of 5 meter. length. Seal the joints with polysulphide sealant, Techseal RDL-940 & Primer RDL-942. Allow it to cure for minimum 24 hours.
  • Seal the joint of parapet wall & roof slab as fillet seal with polysulphide sealant Techseal RDL-940 & Primer RDL-942. Allow the sealant to cure form minimum 24 hours.
  • Apply 1 coat of Techoxy coating as a primer. Being water based it penetrates into the concrete, seals porosity, micro devices, hardens & waterproofs the surface. Allow it dry for minimum 10-12 hours.
  • Apply 2 coats of Techcoat at an interval of 6 hours. Allow the entire waterproofing system to cure for minimum 72 hours before checking leakage test.

Vertical walls & chajjas (externally)
Normally the system used for roof terraces may be applied. For less problematic surfaces, seal the cracks with 1 coat of Techoxy followed by 1 coat of Techcoat.

Mild steel, Galvanised & aluminium water tanks (externally)

Remove rusty scales by high sandblasting / sanding with emery paper / wire brushing. Wipe the surface with solvent (Xylene / Toulene / Acetone etc) soaked cloth.

  • On mild steel surface, apply 1-2 coats of epoxy primer. Apply 2 coats of Techcoat.
  • On Aluminium / galvanised surface, apply 1-2 coats of polyvinyl butyl based wash primer & then apply 1-2 coats of Techcoat

Cleaning of tools & equipments
Tools and equipments should be cleaned with Xylene, Toluene or Acetone solvents

Storage & Shelf-life
The shelf life is twelve months from the date of manufacturing when stored in original unopened conta iners at a temperature between -10°C to +35°C. Materials must be consumed as soon as the containers are opened.

Precautions

Some people are sensitive to resins.hardeners.solvents and its vapours, so it is advisable to use hand gloves and goggles.
While application proper ventilation should be provided.
Avoid application below 10°C temperature of the surface. At low temperatures, drying and curing periods will be prolonged.
Avoid application on damp or moist conditions as it will create blister formation problem.
Do not apply from inside of the tank or room, solvent vapours will pose problem to the
applicator.
Store at cool and dry place.
Before opening part II bottle, place it at a slight inclined angle, away from your body and then open it slowly.

Packing

1,4,20 Litres.



 
Home l Profile l Projects l Products l Services l Branches l Credentials l Recognition l R&D l Clients l Global Partners l Exports l Contact us