PRODUCTS>> Waterproofing Coating

 
/map>

TECHCOAT is a two component, polyurethane polymer based waterproof coating. It cures to form impervious, tough and abrasion resistant, waterproof and weather durable coating. It remains unaffected by salt water, soap water, dilute acids, alkalies and various other chemical solutions. It reflects light and heat.

 

 

Technical Information

Characteristics
 Mixing ratio
Part I : Part II
90:10 parts by volume
 Consistency of the mix   Brushable
 Application time (pot life) at 30ºC
 Surface dry time (Tack free time)
 Hard dry time at 30ºC
 Complete curing time at 30ºC

3-4 hours.
15 to 30 min
8 to 12 hours
2 hours minimum

 Recoatibility time at 30ºC
 Finish
 Dry film thickness

10 to 12 hours
Smooth/ semigloss
40-45 microns/coat

Coverage
    Concrete
    Steel





40-45 sq.ft./lit/coat
70-75 sq.ft./lit/coat


Features / Advantages

  • Cold curing, cures to a tough, flexible and abrasion resistant coating.
  • White in colour, reflects light, UV rays & heat & remains unaffected by exposure.
  • Bonds strongly on cement concrete, asbestos, mild steel, cement plastered and TECHOXY applied surfaces.
  • Resistant to fungus, micro-organisms, water, dilute acids, alkalies, oils and various other chemical solutions
  • Performs well in temperature range of +20ºC to +80ºC
  • Can be tinted with Universal Stainers for light shades.

Application
For waterproofing of

  • External vertical walls of buildings.
  • Building roof terraces
  • Flat or sloppy roofs
  • Chajjas
  • Concrete/steel water tanks (externally)
  • For corrugated AC sheets roofing

Mixing
Pour the entire quantity of Part II into Part I. Mix both the parts thoroughly  by spatula to a homogenous mixture.

Thinner

Techcoat is normally supplied at application viscocity. However, 5% of solvent (Xylene / Toulene) can be used to overcome the problem of fast drying due to hot substrate & sunheat.

Direction for use

Surface preparation

Surface preparation is of great importance & will affect adhesion & life of the coating. Surface should be dry, free from dust, loose particles, damaged plaster, grease, etc. Thorough wire brushing of the surface is a must. Previously applied bituminious coating should be removed. New concrete plastered surface should be cured with water for minimum 28 days.

Waterproofing of Roof Terrace & parapet walls.

  • Repair damaged cement plaster or concrete mortar with Mastercrete M-81, acrylic modifier.
  • Use 5-10% by weight of M-81 on cement weight for the preparation of mortar.
  • Before placing mortar, apply bond coat of O.P. cement & M-81 (2:1 parts by wt). M-81 improves the compression, flexural strength & bonding of new mortar with old concrete surfaces.
  • Cure the repaired mortar for 7 days to 28 days with water before application of Techcoat.
  • Fill the cracks upto 2mm width with Techoxy or Techmast with O.P. cement white / grey (1:2 parts by wt.) putty. Allow to dry for overnight 24 hours.
  • Seal the cracks wider than 2mm with polysulphide sealant Techseal RDL-940 & Primer RDL-942 after making the joint / groove of 5x5 mm or 10x10mm into the crack
  • For large terrace (>3000sq.ft) provide dummy joints at span of 5 meter. length. Seal the joints with polysulphide sealant, Techseal RDL-940 & Primer RDL-942. Allow it to cure for minimum 24 hours.
  • Seal the joint of parapet wall & roof slab as fillet seal with polysulphide sealant Techseal RDL-940 & Primer RDL-942. Allow the sealant to cure form minimum 24 hours.
  • Apply 1 coat of Techoxy coating as a primer. Being water based it penetrates into the concrete, seals porosity, micro devices, hardens & waterproofs the surface. Allow it dry for minimum 10-12 hours.
  • Apply 2 coats of Techcoat at an interval of 6 hours. Allow the entire waterproofing system to cure for minimum 72 hours before checking leakage test.

Vertical walls & chajjas (externally)
Normally the system used for roof terraces may be applied. For less problematic surfaces, seal the cracks with 1 coat of Techoxy followed by 1 coat of Techcoat.

Mild steel, Galvanised & aluminium water tanks (externally)

Remove rusty scales by high sandblasting / sanding with emery paper / wire brushing. Wipe the surface with solvent (Xylene / Toulene / Acetone etc) soaked cloth.

  • On mild steel surface, apply 1-2 coats of epoxy primer. Apply 2 coats of Techcoat.
  • On Aluminium / galvanised surface, apply 1-2 coats of polyvinyl butyl based wash primer & then apply 1-2 coats of Techcoat

Cleaning of tools & equipments
Tools and equipment should be cleaned with Xylene, Toulene or Acetone solvents.

Storage & Shelf-life
12 months from the date of mfg. at a temp. +10ºC to +35ºC. Materials must be consumed once the containers are opened.

Precautions

While application proper ventilation should be provided. Avoid application in damp conditions. It will create blister.

Packing

1,4,20 Litres.



 
Home l Profile l Projects l Products l Services l Branches l Credentials l Recognition l R&D l Clients l Global Partners l Exports l Contact us

© Choksey Chemicals Pvt. Ltd. - Corporate Communication. All rights reserved