Features / Advantages
- Reacts in contact with water
by crystallization
- Does not shrink and crack after
curing
- Can be applied on a wet substrates
- Forms micro porous coating which
allows breathing of the substrate
- Can be applied both indoors and
outdoors.
- Resists both high positive (Hydrostatic)
water pressure (e.g. Swimming Pool)
and high negative (Underground)
water pressure (e.g. Basement).
- Non-toxic, non-dangerous and
odourless.
- It acts by perfectly plugging
pores in masonry.
- Approved for use in drinking
water tanks, reservoirs.
- It has very good resistance to
aggressive, non-mineralised water.
- Can be covered by renderings,
micro-porous paints and tiles (do
not use paints with a closed film,
e.g. enamel paints.
- Can be applied on wet supports,
Use the humidity of the support
to key into
in to the support.
Usage
- TECHFORCE is
used as a protective, waterproofing
system in buildings (Super structures
and Substructures).
For sealing under positive
water pressure
- Drinking water reservoirs, water
tanks- Pits of all kinds
- Agricultural silos
- Swimming pools
- Sea water pools
For sealing under negative water
pressure
- Cellars, basements
- Parking areas
- Lift Shafts
- Garage grease pits
- Galleries, tunnels and sewers
- Below-grade walls
Direction for
use
Surface Preparation
- Surface preparation
is the most important step before
application to get results and to
avoid failure.
- The substrate must be clean and
free of dirt, paint, grease, sludge,
fungus, cement coatings, blistered
and loose plasters etc.
- Moisture is necessary for the
effectiveness of TECHFORCE. Therefore,
wash & saturate the surface
with water before applying coating,
however, streaming water must be
diverted by creating drains.
- For appplication on dry or hot
walls, wet the walls with water
thoroughly before application. Avoid
application under direct sunlight.
- Do not apply in rain or if there
is risk of freezing.
- Before application of TECHFORCE,
seals the cracks with Polysulphide
Sealant TECHSEAL RDL-940. After
the application of PRIMER RDL- PRIMER
RDL – 942.Tool the sealant to a
uniform leveled surface
Application Method
- Apply the first coat of TECHFORCE
at 1kg/sq.m. laying it on generously
in
order to plug the pores and shrinking
cavities.
- After 24 hours, dampen then apply
the second coat at 0.800 kg/sq.m.
- Apply a third coat in the same
way, if necessary.
- Moisten or wet the surface between
two coats.
- Mixed material can be applied
with a small or large brush or with
a trowel.
- One coat is sufficient for a
good protection against dampness.
2 or 3 coats are necessary if water
pressure is very high.. It wil resist
a negative water pressure upto 1
kg//sq.cm.
Mixing
Pour clear water in a bucket and add
TECHFORCE slowly obtaining thick creamy
paste. It is advisable to mix with
electrical stirrer at slow speed until
a homogenous paste without lumps is
obtained. The consistency of the mixture
should enable a good and smooth application
by brush. If necessary, the mixture
can be diluted slightly by mixing
1% clean water to facilitate the smoothening
of second coat.
Table of consumption depending
upon water pressure
Negative Pressure
100 gm/sq.cm
300 gm/sq/cm
1000 gm/ sq.cm |
Consumption per sq.mtr
1.5 kg.
2.5 kg.
3.5 kg. |
| |
|
Precaution
- Do not apply on dry or hot substrates
or direct sunlight
- Do not apply in rain or if there
is a risk of freezing, i.e. temperature
lower
than 4°C.
- TECHFORCE coating is cement based
product therefore, must be used
as a
pasty cement coating and not as
white wash.
- Shelf life of the unmixed material
is one year from the date of manufacture.
- Store in cool and dry place
- In case of application in very
hot or windy weather, plan to dampen
the TECHFORCE during its setting
to avoid drying too fast, which
would cause the coating to ‘burn’.
Packing
25 kg
Note
It is recommended that this coating
should be overcoated with microporous
paints,which will not disturb the
breathing of TECHFORCE a well as wall.
|