Features / Advantages
- Dry Film Contains 80% of Zinc
Dust.
- Provides optimal galvanic protection
for steel.
- Excellent chemical resistant
base for high
- Performance topcoats
- Protects metal substrate exposed
to corrosive environments
Typical Application
- Corrosive Industrial environments
- Marine or Offshore structures
- High humidity or coastal areas
- Cooling Towers
- Chemical plants
- Water or waste treatment plant
- Fertilizer plants
- Priming structural steels, pipes,
bridges and barges.0
Certification
Formulated without lead, Mercury,
or chromates.
Formulated with non photo chemically
reactive solvents. Does not contain
any ozone-depleting substrates, either
Class I or Class II
Direction
for use
Bare Steel
All surfaces shall be free of rust,
mill scale, and contaminants such
as oil, grease, dirt, and salts. Before
any surface preparation is attempted,
oil and grease must be removed by
employing SSPC- SP1 solvent cleaning.
For large areas use oil and grease
emulsifier.
For Best performance
Use commercial blast cleaning to SSPC-
SP6 to remove mill scale, rust and
other contaminants and leave a roughened
surface.
Use power tool cleaning to bare metal
SSPC- SP11 to remove mill scale, rust
and other contaminants and leave a
roughened surface.
Application Information
Generally, Techguard 101
is best applied by spray. Due to the
rapid dry of this coating only small
areas may be coated by brush applicator
pad or roller must be taken to achieve
the specified wet and dry thickness
uniform even coats must be obtained.
Application Equipment:
DeVilbis or Equivalent Equipment
Air spray: MBC 510 Gun (stainless
steel) “E” tip and fluid
needle, 64 or 765 Air Cup, Mastic
Spring, Teflon Packing. Maximum of
5 ft. 5/16" (7. 94 MM) I.D. Air
and 1/2 " (12.70 MM) I.D. Fluid
Hose
Atomization Pressure: 50 PSI
Fluid Pressure: 15 PSI
Airless Spray: Utilize only equipment
recommended by manufacturer as being
suitable for application of Zinc Rich
Products. Continuous agitation of
mixed material is required during
application.
Equipment must be capable of maintaining
1500 PSI at the Tip.
Hose length in excess of 25 ft. and
work at heights greater than 10 ft.
above the pump are vto is avoided.
These conditions promote zinc setting
in the fluid hose with resulting top
plugging and non uniform distribution
of zinc in the applied film.
Repair of Damaged Spots:
This product is also recommended for
filed touch up of shop applied inorganic
zinc primer prior to application of
high performance topcoats.
Precaution
DANGER! FLAMMABLE!
Contains xylene. Keep away from heat,
sparks and flame. Avoid breathing
vapour. Use with forced air ventilation
in confined areas. Avoid contact of
resin or hardener with skin or eyes.
In case of eye contact, flush immediately
with plenty of water and consult a
physician. Do not take internally.
- Not to be applied when air and
surface temperatures are bellow
50°F
- Must be top coated with appropriate
coating when used in corrosive
environments
- Caution when opening containers-
gassing may occur
- Not for immersion or for exposure
to acids & alkalies without
proper topcoats.
Packing: