PRODUCTS>> Admixture

 
/map>


MASTERPLAST SPL-9 is a unique superplasticising admixture for cement concrete and mortar. It retains the workability of concrete for few hours. It enables water requirement to be reduced for a given workability at low dosages. It retains the workability of concrete in proportion to the amount of admixture used. It is more used in situations where workability retention is needed. Water reduction upto 40% can be affected.


Technical Information

Characteristics

 Nature
 Colour

:
:
Single component, Liquid
Brown
 pH Value
 Specific Gravity at 30°C
 Viscosity
:
:
:
7-9
1.27± 0.02
Medium viscous liquid.
 Engineering Data

 

 Setting time at 30°C
 - No admixture
 - 4 Hours





0.2 ltr. per 50 kg cement
5 ½ hours
 Compressive strength
 % control


:




3 days -125%
7 days -115%
28 days -110%

 Flexural strength %  control


:


3 days -100%
7 days -100%
28 days -110%

 

 

 

Features / Advantages

  • It controls the rate of setting of concrete and mortars.
  • It improves workability and easier handling.
  • It retains the workability upto three hours.
  • It reduces segregation and bleeding.
  • It can be used even for micro silica, fly ash and slag cement concrete
  • It improves finished appearances of the hardened concrete.
  • It reduces shrinkage and permeability of hardened concrete.
  • It increases strength of the concrete and mortar.
  • It reduces cracking.
  • It eliminates formation of cold joints between subsequent pours in mass or structural concrete.
  • It entrains minimal air without affecting strength parameters.
  • It is based on Sulphonated Naphthalene formaldehyde polymer.
  • It does not contain chlorides or nitrates.


Usage

  • It is widely used in ready mix concrete.
  • Masterplast SPL-9 is particularly recommended for concreting in hot climates, long or difficult pours, prestressed concrete in large sections or mass concreting.
  • It is used in concrete of all classes.
  • • It is used more specifically in:
    - Pavement concrete
    - Structural concrete
    - Bridge decks & Highway concrete
    - Light weight concrete and Expansive concrete.


Specifications Complies

  • Indian Standard specification IS:9103
  • British Standard specification BS:5075 Part 3
  • American Standard Testing Materials ASTM-C-494 Type D and Type G


Directions For Use:

Dosage:

To get the required workability retention of concrete mixes depends upon the ambient temperature and other factors. Hence trial mixes should therefore be performed. The normal dose is 0.05 to 0.75 ltr. per 50 kgs. of cement. A dosage upto 1 litre per 50 kgs. of cement can be used when micro silica, fly ash, slag cement etc, are present in the mix. Masterplast SPL-9 should be added to the wet mix or mixing (gauging) water. It should not be added to dry cement. For addition of Masterplast SPL-9 a dispenser or exact measuring container is recommended. Stir well before use.

Cleaning Of Tools & Equipments
Tools and equipments can be cleaned with Water.

Storage And Shelf Life

  • Store the material at a cool & dry place (preferably at 30°C Temp. or at room temperature).
  • Shelf life is two years.
  • It will freeze at (thawing) temperatures but can be reconstituted by stirring.

Packing
5 Litre, 20 Litre, 200 Litre, or as per requirement.


Precautions

  • Do not mix it with dry cement
  • Add to mixing (gauging) water or directly to the mix.
  • Stir well before use.
Stir well before use.



 
Home l Profile l Projects l Products l Services l Branches l Credentials l Recognition l R&D l Clients l Global Partners l Exports l Contact us

© Choksey Chemicals Pvt. Ltd. - Corporate Communication. All rights reserved